COMPONENTS BLACKLIST

LIST OF COMPONENTS THAT MUST NOT BE USED

SUPPLIER TYPE DESCRIPTION REASON ALTERNATIVE
Siemens PLC series 12xx, 1510 to 1515 PLC Cannot use our sequencer, our components, or technology objects for Siemens frequency converters. Small memory, only one network card. Siemens 1516, 1517, 1518 V4.0+
Siemens PLC with firmware lower then 4.0 PLC Not suitable for high communication load Siemens 1516, 1517, 1518 V4.0+
ANY IOlink device IOlink master or slave No support for IOlink in Simatic AX Siemens ET200AL boxes DI/AI boxes
Siemens any old HMI Panels except Unified with firmware 20.2+ HMI Panel Has to be capable to open browser that supports .NET8, I guess Unified with firmware 20.2+ at least 20inch at least 1920*1080 resolution
Festo with Siemens PLC Pneumatic manifolds with EtherCAT Pneumatic manifolds with EtherCAT Siemens does not support EtherCAT bus Festo manifolds with PROFINET
Aventics with Siemens PLC Pneumatic manifolds with EtherCAT Pneumatic manifolds with EtherCAT Siemens does not support EtherCAT bus Aventics manifolds with PROFINET
Cognex Insight with firmware lower then 24.0.0 Insight family Communication structure does not fit the somponent structure Insight with firmware higher then 24.0.0 or Keyence :-)
ANY GW INSTEK - PSP-2010 LABORATORY POWER SUPPLY UNRELIABLE COMMUNICATION. REQUIRES ADDITIONAL 12V SUPPLY TO USE RS232 INTERFACE TTi QL355
ANY WD My Cloud EX2 Network Drive, NAS Cannot schedule shutdown via UPS Synology DiskStation DS216j 2x 1 TB RED
IAI ALL (!) Intelligent Actuators Each type is different, very poor support, each has different parameterization, inconsistent software for control, inconsistent connection cables, inconsistent parameters... Festo, Schneider
ANY Fujitsu Network Drive, NAS Slow service startup, ping issues after standby and startup. Could not be pinged after link activation Synology DiskStation DS218+, 2x HDD
Ateq Ateq with RS232 Leak Tester Our component is not adapted for it(1), requires additional serial card Ateq with PROFINET, or Ateq without results (OK/NOK only)
Rexroth CtrlX Drives Unstable internal firmware that occasionally gets stuck and cannot be reset in case of an error. The only way to recover is to power it off and on again. Poor technical support. Festo, Schneider

(1) Development would take up our precious time, hence it is inefficient for us.